Paper · 1978 · Silva Fennica

An electronic auxanometer for field use.

Jyrki Hari; Pertti Hari; Markku Kanninen

2
claims
2
verbatim quotes
3
citations
2
research areas
✓
Open access · cc-by-sa

Abstract

This paper describes the design and functioning of an electronic auxanometer designed for field use, and some results obtained with it. The changes in stem radius are monitored with a micrometer screw turned by an electirc motor. A potentiometer transforms the position of the screw into an electronic signal, which is recorded. The accuracy of the device is approximately 1â2 μm. Field experiments with the auxanometer are described and discussed. The accuracy of the device was found to be sufficient for measuring hourly changes in stem radius. The PDF includes a summary in Finnish.

Abstract from the paper’s OpenAlex record; open copy licensed cc-by-sa. Read at the source ↗

The text the model read, with the source record’s inline markup (italics, sub- and superscripts) rendered and its character entities decoded; quote offsets refer to the raw text.

Claims 2

Method / resourceobservedoriginal resultmeasured

Claim · model-written summary

The accuracy of the device is approximately 1â2 μm.

Outcome
accuracy of the devicee0
Value
1â2 μme0

Not reportedTaxon

Verbatim

e0

“The accuracy of the device is approximately 1â2 μm.”

✓ located verbatim in the source · abstract, characters 329–380 · show in text ↑
Method / resourceobservedoriginal resultpositivemeasured

Claim · model-written summary

The accuracy of the device was found to be sufficient for measuring hourly changes in stem radius.

Outcome
measuring hourly changes in stem radiuse0
Comparator
sufficiente0

Not reportedTaxon

Verbatim

e0

“The accuracy of the device was found to be sufficient for measuring hourly changes in stem radius.”

✓ located verbatim in the source · abstract, characters 449–547 · show in text ↑