Paper · 2014 · Plant Pathology

Development of a lateral flow device for in‐field detection and evaluation of PCR ‐based diagnostic methods for Xanthomonas campestris pv. musacearum , the causal agent of banana xanthomonas wilt

J. Hodgetts; G. Karamura; G. Johnson; et al.

6
claims
6
verbatim quotes
27
citations
2
research areas
✓
Open access

Abstract

Xanthomonas campestris pv. musacearum (Xcm) is the causal agent of banana xanthomonas wilt, a major threat to banana production in eastern and central Africa. The pathogen is present in very high levels within infected plants and can be transmitted by a broad range of mechanisms; therefore early specific detection is vital for effective disease management. In this study, a polyclonal antibody (pAb) was developed and deployed in a lateral flow device (LFD) format to allow rapid in‐field detection of Xcm. Published Xcm PCR assays were also independently assessed: only two assays gave specific amplification of Xcm, whilst others cross‐reacted with non‐target Xanthomonas species. Pure cultures of Xcm were used to immunize a rabbit, the IgG antibodies purified from the serum and the resulting polyclonal antibodies tested using ELISA and LFD. Testing against a wide range of bacterial species showed the pAb detected all strains of Xcm, representing isolates from seven countries and the known genetic diversity of Xcm. The pAb also detected the closely related Xanthomonas axonopodis pv. vasculorum (Xav), primarily a sugarcane pathogen. Detection was successful in both naturally and experimentally infected banana plants, and the LFD limit of detection was 10 5 cells mL −1 . Whilst the pAb is not fully specific for Xcm, Xav has never been found in banana. Therefore the LFD can be used as a first‐line screening tool to detect Xcm in the field. Testing by LFD requires no equipment, can be performed by non‐scientists and is cost‐effective. Therefore this LFD provides a vital tool to aid in the management and control of Xcm.

Abstract from the paper’s OpenAlex record, shown for indexing and research. Copyright remains with the authors or the publisher. Read at the source ↗

The text the model read, with the source record’s inline markup (italics, sub- and superscripts) rendered and its character entities decoded; quote offsets refer to the raw text.

Claims 6

Method / resourceobservedoriginal resultmixedmeasured

Claim · model-written summary

Of the published Xcm PCR assays independently assessed, only two gave specific amplification of Xcm.

Outcome
specific amplification of Xcme0
Value
only two assayse0

Verbatim

e0

“only two assays gave specific amplification of Xcm”

✓ located verbatim in the source · abstract, characters 568–618 · show in text ↑
Method / resourceobservedoriginal resultpositivemeasured

Claim · model-written summary

The polyclonal antibody detected all Xcm strains tested, representing isolates from seven countries.

Taxon
Xcme0
Outcome
detected all strains of Xcme0
Value
seven countriese0

Verbatim

e0

“the pAb detected all strains of Xcm, representing isolates from seven countries”

✓ located verbatim in the source · abstract, characters 906–985 · show in text ↑
Observationobservedoriginal resultmeasured

Claim · model-written summary

The polyclonal antibody also detected the closely related Xanthomonas axonopodis pv. vasculorum, primarily a sugarcane pathogen.

Taxon
Xanthomonas axonopodis pv. vasculorumXanthomonas axonopodis pv. vasculorume0
Outcome
also detectede0

Verbatim

e0

“The pAb also detected the closely related Xanthomonas axonopodis pv. vasculorum (Xav), primarily a sugarcane pathogen”

✓ located verbatim in the source · abstract, characters 1026–1143 · show in text ↑
Observationobservedoriginal resultpositivemeasured

Claim · model-written summary

Xcm was successfully detected in both naturally and experimentally infected banana plants.

Taxon
bananae0
Outcome
Detection was successfule0

Verbatim

e0

“Detection was successful in both naturally and experimentally infected banana plants”

✓ located verbatim in the source · abstract, characters 1145–1229 · show in text ↑
Method / resourceobservedoriginal resultmeasured

Claim · model-written summary

The limit of detection of the lateral flow device was 10 5 cells mL −1.

Outcome
limit of detectione0
Value
10 5 cells mL −1e0

Verbatim

e0

“the LFD limit of detection was 10 5 cells mL −1”

✓ located verbatim in the source · abstract, characters 1235–1282 · show in text ↑
Recommendationauthor interpretationoriginal resultpositivebasis n/a

Claim · model-written summary

The authors conclude the lateral flow device can be used as a first-line screening tool to detect Xcm in the field.

Taxon
Xcme0
Outcome
first‐line screening toole0

Verbatim

e0

“the LFD can be used as a first‐line screening tool to detect Xcm in the field”

✓ located verbatim in the source · abstract, characters 1377–1454 · show in text ↑