Maximum field capacity was 3.32 fed/h with a flat-fan nozzle at 10 bar and 4.6 km h −1.
- Taxon
- grapet0
- Treatment
- flat-fan nozzle, 10 bar pressure, and a forward speed of 4.6 km h −1e0
- Outcome
- field capacitye0
- Direction
- maximume0
- Value
- 3.32 fed/he0
Not reportedMaterialGeneCompoundOrgan / stageInteractorInteractor roleSecond interactorSecond interactor roleComparatorSettingQualifier
Verbatim
e0“The maximum field capacity of 3.32 fed/h was recorded with a flat-fan nozzle, 10 bar pressure, and a forward speed of 4.6 km h −1”
t0“grape”
Title
Developing a pesticide spraying machine suitable for grape orchards
M.A. Aboegela; Mohamed Elmeadawy; Mahmoud Okasha; et al. Progress in Agricultural Engineering Sciences 2026. doi:10.1556/446.2026.00304
Other claims from this paper (4)
- Method / resource Flat-fan nozzles at 20 bar and 2.4 km h −1 achieved the highest droplet density, 197 droplets/cm 2.
- Method / resource The highest forward speed gave the lowest droplet density, 73 droplets/cm 2.
- Method / resource Mean droplet diameter decreased as pressure increased.
- Method / resource The smallest mean droplet diameter was 170 μm with the hollow-cone nozzle at 20 bar and 4.6 km h −1.